W skrócie
- An insulated body only has insulated walls. A refrigerated body adds a unit that keeps a set temperature.
- An insulated body works on short routes when the load is pre-cooled and the temperature difference is small.
- Normal insulation means K ≤ 0.70 W/m²K, heavy insulation K ≤ 0.40 W/m²K. Refrigerated classes B, C, E and F require heavy insulation.
- The unit adds purchase cost, weight and service cost, but gives temperature control for the whole route.
- K ≤ 0.70 W/m²K, normal insulation (IN)
- K ≤ 0.40 W/m²K, heavy insulation (IR)
- 6 years validity of the first ATP certificate
Insulated and refrigerated side by side
| Feature | Insulated | Refrigerated |
|---|---|---|
| Refrigeration unit | none | yes, independent or dependent |
| Temperature control | passive, temperature drifts over time | active, holds the set point |
| ATP marking (examples) | IN, IR | FNA, FRA, FRC |
| Tare weight | lower | higher by the unit and its installation |
| Purchase and service cost | lower | higher, plus unit servicing |
| Typical use | bakery, urban distribution of pre-cooled goods | meat, dairy, frozen food, pharma, international routes |
When an insulated body is enough
An insulated body makes sense when the route is short, the load goes into the box already at its target temperature and the doors are opened rarely. Good insulation then holds conditions for a few hours. Bread delivery or distribution within one city are typical examples.
Check whether the consignee asks for temperature records. If so, a recorder can be fitted in an insulated body too.
When you need a refrigerated body
A refrigerated body is needed when the temperature must hold regardless of driving time, weather and the number of door openings. That covers frozen food, fresh meat, dairy and pharmaceuticals, as well as longer routes. For international carriage of perishable food the vehicle needs an ATP certificate of the class that matches the load.
The K coefficient and ATP markings
The K coefficient describes how much heat passes through the body walls. Normal insulation (N) is K no higher than 0.70 W/m²K, heavy insulation (R) K no higher than 0.40 W/m²K. IN or IR markings apply to insulated bodies. A first letter F means a mechanically refrigerated body and the last letter, e.g. C, gives the temperature class.
The first ATP certificate for a new vehicle is issued for up to six years. It is then extended after a test under the rules of the country of registration.
Questions to answer before choosing
- What temperature does the load need: and must it be held, or just not drift too far
- How long is the route: and how many door openings a day
- Does the consignee require temperature records
- Will the vehicle run abroad: then an ATP certificate is required
- How much does payload matter: the unit adds weight
Frequently asked questions
Can an insulated body have an ATP certificate?
Yes. Insulated bodies are marked IN (normal insulation) or IR (heavy insulation).
Can an insulated body be converted into a refrigerated one later?
Sometimes, if the insulation meets the class requirements and the builder planned space for a unit. Confirm it with the body builder and an ATP test station.
Which body is lighter?
The insulated body, because it has no refrigeration unit or installation.
Sources
- UNECE: ATP Agreement, Annex 1 (treaty text)
- UNECE WP.11: ATP classes A–F, mechanically refrigerated equipment
- Cemafroid: ATP marking and certificate lifecycle
- GOV.UK: ATP rules on carrying perishable foodstuffs
Trucklo routes truck bodywork enquiries to manufacturers who build them.